Appendix APPENDIX A) .1) Using 24v 2A Internal Supply for Detectors
There is spare capacity on the 24v power supply. The exact amount depends upon the
number of Expansion I/O Boards and their equivalents (1 SDE/SA Board @ 250mA is
equivalent to two Expansion I/O Boards @ 2 x 125mA). e.g. 5 equivalents represent 3
Exp I/O + 1 SDE/SA.
The use of the internal 24v power supply is also dependent upon the distance rules see
the following section.
Table APPENDIX A) -1) Using the 24v 2A Internal Supply For Detectors
The following table indicates the maximum number of detector cards the T400 is
capable of supporting on the 24v 2A internal supply, given the number of expansion
I/O boards fitted (or equivalent) and the type of detector card:-
Expansion I/O Equivalents 0 1 2 3 4 5
Siemens and Microsense 2- and 4-Channel (220mA) 8 8 7 6 6 5
Sarasota 4-Channel MCE28Z (370mA) 5 4 4 4 3 3
Sarasota 4/2/1-Channel MTS38Z/36Z/35Z (160mA) 11 11 10 10 8 8
24v +20% 8VA Above Ground Detectors (333mA) 554333
i.e. The controller is capable of supporting at least 5 Siemens detector cards (subject to
distance) even when fully equipped.