Engineer programming via the keypad
5. Press ENTER to save the new time.
If an attempt is made to save an invalid time value, the text INVALID
VALUE is displayed for 1 second and the user is prompted to enter a valid
time.
14.20 INSTALLER TEXT
This setting allows the engineer to enter system information and engineer contact
information.
1. Scroll to INSTALLER TEXT and press SELECT.
2. Scroll to the desired programming option:
Used to help identify the system; use a clear and descriptive name for
the installation.
Used to help identify the installation when connected to a central
station (max. 10 digits).
Used for contact purposes.
Used for contact purposes.
Setting to display installer details can during the idle state.
The installer contact details programmed in these menu options should also be
entered on the keypad pull-down label on completion of the installation.
14.21 DOOR CONTROL
This option allows you to control all the doors of the system.
1. Scroll to DOOR CONTROL and press SELECT.
2. Select the door which should be controlled and press SELECT.
3. Select one of the door states listed below as new door state and press
The door is in normal operation mode. A card with the corresponding
access rights is needed to open the door.
The door is opened only for a timed interval to allow access.
The door is locked. The door remains closed even if a card with the
corresponding access rights is presented.