Seitenansicht 91
14
Engineer programming via the keypad
WIRELESS
92
Siemens AB
A6V10276959
Security Products
18.11.2011
SUPERVISION
Enable or disable tamper supervision.
FILTER LOW
SIGNAL
Enable or disable the filter low signal (RF strengths 0 and 1).
DETECT RF JAM
Enable or disable the RF JAM.
RFFOB PANIC
Enable or disable the RFFob Panic or enable silent mode for the
RFFob Panic.
WPA TEST
SCHEDULE
Enter a maximum period (in days) between WPA tests. Max is 365
days.
PREVENT SET
TIME
Enter a time in minutes after which, if the sensor or WPA fails to
report, a setting is prevented for an area where the wireless zone is.
Max is 720 minutes.
DEVICE LOST
TIME
Enter the number of minutes after which the wireless device is
reported as lost if it fails to report within this timeframe. (Min is 20
and max is 720 minutes)
14.6.1 ADD SENSORS
To add a wireless sensor device:
1. Scroll to ADD and press SELECT.
The prompt ACTIVATE ENROL is displayed.
2. Press SELECT.
The top line of the display flashes the text ACTIVATE DEVICE.
3. Activate the wireless device between 3 and 5 times in succession to allow the
keypad receiver to detect the wireless transmission of the device.
The display indicates that the device has been detected by flashing the text
FOUND SENSOR. The device TYPE and ID information is displayed
alternately.
4. Press ENROL.
A prompt to select the zone type is displayed.
1. Press SELECT.
2. Scroll to the required zone type and press SELECT.
To add a device by TAMPER ENROL, scroll to this option in step 2. The
enrolment process is identical except a prompt to define an area type is displayed
before the zone type prompt.
14.6.2 EDIT SENSORS (ZONE ASSIGNMENT)
It may be necessary to change the zone assignment of sensor enrolled on the
system.
To change the zone assignment of a wireless detector:
1. Scroll to EDIT and press SELECT.
2. Scroll to the sensor to be changed and press SELECT.