Engineer programming via the browser
external) from the drop down menu. The type of antenna required for the
wireless module depends on the type of wireless module fitted.
Select whether a wireless sensor that is reported as missing registers a
tamper condition on the signet panel. A wireless sensor is reported as
missing when no supervision signal has been received from the sensor for a
period greater than the programmed Wireless Lost timer.
See page [➙ 160].
Tick to filter low strength RF signals.
Tick to activate an alert if RF interference is detected.
Select how the Panic buttons on the RF Fob should operate.
Enter a maximum period (in days) between WPA tests.
Enter a time in minutes after which, if the sensor fails to report, a setting is
prevented for an area where the wireless zone is.
Enter a number of minutes after which the wireless device (sensor or WPA)
device is reported as lost.
15.11.3 Configuring a WPA
The WPA configuration and status page is displayed only if there is a wireless
module fitted on the panel or any of its expanders, and the panel is licensed for
the type of module(s) fitted.
A WPA is not assigned to a user. Usually, a WPA is shared by several people, for
example, security guards working in shifts or, alternatively, WPAs may be
permanently attached to a surface such as under a desk or behind a till.
A maximum of 128 WPAs is allowed per panel.
To configure a WPA from the browser:
Select Full Engineer mode and select the following options
Settings>Wireless>WPA.
The following items can be checked or configured from this page:
Battery Status