Engineer programming via the browser
Configuring zones, doors and areas
Each free zone number can be assigned to the zones but the assignment is not
fixed. If the number ‘9’ is assigned to a zone, the zone and an input expander with
the address ‘1’ is connected to the X-Bus (which is using the zone numbers 9-16).
The assigned zone from the two door controller will be moved to the next free
zone number. Configuration will be adapted accordingly.
Door attributes
If no attribute is activated, a valid card or a PIN can be used.
The card is temporarily blocked.
Used when multiple doors are assigned to the same area
and/or anti passback, custodian, or interlock functionality is
required.
Card and PIN are required to gain entry.
PIN is required. No card will be accepted.
PIN or card are required to gain entry
PIN is required on exit reader. Door with entry and exit
reader is required.
PIN is required to set and unset the linked area. The card
has to be presented before the PIN is entered.
Panel/area will unset, when card is presented at entry
reader.
Panel/area will unset, when card is presented at exit reader.
Panel/area will fullest, when card is presented twice at entry
reader.
Panel/area will fullest, when card is presented twice at exit
reader.
Door lock opens if a fire alarm is detected within the
assigned area.
The escort feature enforces privileged card holders to
escort other card holders through specific doors. If this
feature is assigned to a door, a card with the “escort right”
has to be presented first, to allow other cardholders without
this right to open the door. The time period in which
cardholders are able to present their cards after a card with
escort right was presented, can be configured per door.
Anti-passback should be enforced on the door. All doors
must have entry and exit readers and must be assigned to a