15
Engineer programming via the browser
Configuring advanced settings
236
Siemens AB
A6V10276959
Security Products
18.11.2011
Enable
Tick this checkbox to enable EDP operation on the system.
EDP Panel ID
Enter a numeric identifier that is used by the EDP Receiver to identify the
panel uniquely.
Panel Port
Select the IP port for receiving IP packets. Default is 50000.
Packet Size Limit
Enter the maximum number of bytes in an EDP packet for transmission.
Event timeout
Enter the timeout period (in seconds) between retransmissions of
unacknowledged events.
Retry Count
Enter the maximum number or event retransmissions allowed by the system.
Dial Attempts
Enter the maximum number of failed dial attempts accepted by the system
before the modem is locked out (prevented from making further attempts to
dial). The lockout period is defined in the option Dial Lockout.
Dial Delay
Enter the time period (in seconds) that the system will wait before redialling
after a dial attempt has failed.
Dial Lockout
Enter the time period (in seconds) that the system will suspend dialling when
the maximum number of failed dial attempts is reached. Enter a value of ‘0’ to
continually attempt dialling.
Event Logging Options
Comms Status
Log all communication availability.
EDP Commands
Log all commands executed through EDP.
A/V Events
Log when Audio/Video verification events are sent to Receiver.
A/V Streaming
Log when Audio/Video live streaming begins.
Keypad Use
Log when remote keypad is activated.
15.12.9 Remote Maintenance
For further information please refer to the Remote Maintenance Configuration
Manual.
15.13 Configuring advanced settings
15.13.1 Calendars
Select Settings > Advanced > Calendars.
Calendars are used for scheduling time-based control within 2 groups:
Autosetting of areas (Automatic Setting and/or Unsetting)
All other purposes (includes triggers, enabling of users, zones, physical
outputs, e tc . )
A calendar can be used for multiple purposes with the operations differing based
on the classifications above. At any moment in time and as defined in the settings,
Seitenansicht 235