Engineer programming via the keypad
14
DOORS
95
Siemens AB
A6V10276959
Security Products
18.11.2011
Door inputs
Each door has 2 inputs with predefined functionality. These two inputs, the door
position sensor and the door release switch can be configured.
Zone
The door position sensor input can be used for the intrusion part as well. If
the door position sensor input is used also for the intrusion part, the zone
number it is assigned to has to be selected. If the door position sensor is
used only for the access part, the option “UNASSIGNED” has to be
selected.
If the door position sensor is assigned to an intrusion zone, it can be
configured like a normal zone but only with limited functionality (e.g. not all
zone types are selectable).
If an area or the system is set with the card reader, the door position
sensor input has to be assigned to a zone number and to the area or the
system which have to be set.
Description
Description of the zone the door position sensor is assigned to.
Zone Type
Zone type of the zone the door position sensor is assigned to (not all
zones types are available).
Zone attributes
The attributes for the zone the door position sensor is assigned to can be
modified.
Area
The area the zone and the card reader are assigned to. (If the card reader
is used for setting & unsetting, this area will be set / unset).
Door Position
The resistor used with the door position sensor. Choose the used resistor
value / combination.
DPS Normal
Open
Select if the door release switch is to be a normally open or normally
closed input.
Door Release
The resistor used with the door release switch. Choose the used resistor
value / combination.
DRS Normal
Open
Select if the door release switch is a normally open input or not.
Each free zone number can be assigned to the zones but the assignment is not
fixed. If the number 9is assigned to a zone, the zone and an input expander with
the address ‘1’ is connected to the X-Bus (which is using the zone numbers 9-16).
The assigned zone from the two door controller will be moved to the next free
zone number. Configuration will be adapted accordingly.
Door Groups
The different doors can be assigned to door groups. This is needed if one of the
following functionalities is activated:
Custodian
Soft Passback
Prevent Passback
Interlock