The transmitter ID is printed on the WPA casing and can be entered
manually here.
You can also identify the ID remotely by pressing any button on the WPA
and then clicking the Learn button. The panel automatically enters this ID in
this field providing no other WPA is currently defined with it
The WPA may be configured to send periodic supervision signals.
Supervision is enabled on the WPA with a jumper.
The supervision function also needs to be enabled on the panel for the
particular WPA for correct supervision operation. If the panel does not get a
supervision signal, it raises an alarm that is shown in the keypad and logged.
If supervision is not enabled, the WPA sends out a supervision message
about every 24 hours to transmit the WPA battery status to the panel. This
message is also randomized to decrease the chances of collision with other
WPAs.
Tick the Supervise box if supervision has been enabled for that particular