Engineer programming via the browser
15
Configuring controller inputs & outputs
187
Siemens AB
A6V10276959
Security Products
18.11.2011
Panic*
This output turns on following activation of panic alarm zone types from any area. A
panic alarm output is also generated if a user duress event is generated or if the panic
option for the keypad is enabled.
Hold-up
This output turns on whenever a zone programmed as a Hold-up type zone triggers an
alarm from any area
Fire
This output turns on following a fire zone activation on the system (or from any area)
Tamper
This output turns on when a tamper condition is detected from any part of the system.
For a grade 3 system, if communication is lost to an XBUS device for greater than
100s, a tamper is generated and SIA and CIR reported events will send a tamper.
Medical
This output turns on when a medic zone is activated
Fault
This output turns on when a technical fault is detected
Technical
This output follows tech zone activity
Mains Fault*
This output activates when Mains power is removed
Battery Fault*
This output activates when there is a problem with the backup battery. If the battery
voltage drops below 11 V this output activates. The ’Restore’ option for this fault is only
presented when the voltage level rises to above 11.8 V.
Partset A
This output is activated if the system or any area defined on the system is in Partset A
mode
Partset B
This output is activated if the system or any area defined on the system is in Partset B
mode
Fullset
This output is activated if the system is in Fullset mode
Fail to set
This output activates if the system or any area defined on the system failed to set; it
clears when the alert is restored
Entry/Exit
This output activates if an Entry/Exit type zone has been activated; i.e. a system or
area Entry or Exit timer is running
Latch
This output turns on as defined in the system latch output configuration (see
Configuring system latch and auto set outputs [ 188]).
This output can be used to reset latching sensors as smoke or inertia sensors.
Fire Exit
This output turns ON if any Fire-X zones on the system are activated
Chime
This output turns on momentarily when any zone on the system with chime attribute
opens
Smoke
This output turns on momentarily when a user unsets the system; it can be used to
reset smoke detectors
Walk Test*
This output turns on momentarily when a walk test is operational and a zone becomes
active. This output can be used, for example, to activate functional tests of connected
detectors (if available).
Auto Set
This output turns on if the Auto Set feature has been activated on the system.
User Duress
This output turns on if a user duress state has been activated (PIN code + 1 has been
entered on the keypad)
PIR Masked
This output turns on if there are any masked PIR zones on the system. It generates a
fault output on the keypad led.