Engineer programming via the browser
Enter a unique description to identify the keypad.
Function Keys (in idle state)
Select Enable, Disable or Enabled Silent. If enabled, panic alarm is activated by
pressing the 2 soft keys together.
Select when keypad backlight is on. Options are: - On after key is pressed;
Always on; Always off..
Enable or disable the LED’s on the keypad.
Select if setting state should be indicated in idle mode.
Enable or disable the buzzer on the keypad.
Enable or disable buzzer during exit time on Partset.
Select if the speaker volume for the key presses should be activated.
Select if the keypad should be limited by calendar. See Calendar [➙ 236].
Select if keypad should be limited by a mapping gate.
Select if keypad should be limited by a keyswitch.
Tick this box to disable the keys on the keypad during the entry time when a
PACE is configured on the keypad.
Select the secured area where the keypad is located.
Select which areas can be controlled through keypad.
Select to configure a delayed set across all keypads. The location of the keypad
is ignored and all areas will perform a full exit time count down.
An area should be assigned to a keypad only if the keypad is inside the assigned
area, and if an entry/exit route is defined. If an area is assigned, when the
particular area is set or unset then entry and exit timers are used (if configured).
Other features related to entry/exit routes also become available. If no area is
assigned, the area is set or unset immediately and other entry/exit features are
not available
See also
Calendars [➙ 236]