Engineer programming via the browser
System Options
The options displayed vary depending on the Security Grade of the system.
Enables multiple areas on the panel.
Enable to activate relevant bells/sirens on an unconfirmed
alarm. When this option is disabled, the relevant bells/sirens
will only activate on a confirmed alarm or if the detector that
caused the unconfirmed alarm is reactivated.
Enable to resound bells/sirens if a second zone activation is
detected (after the bell time has elapsed). If not checked
then the external bells will only trigger once.
Bell on Fail to Set (FTS)
Enable to activate the internal bell if the system fails to set.
Strobe on Fail to Set
(FTS)
Enable to activate the strobe if the system fails to set.
If enabled, key fob is enabled to restore alerts by pressing
the Unset key.
Always Show State
(SHOW STATE)
If enabled, the setting status of the system (Fullset / Partset /
Unset) is permanently displayed in the bottom line of the
keypad display. If unchecked the setting status will
disappear from the keypad display after 7 seconds.
If enabled, open zones will display on keypad in Unset
mode.
If enabled, the ARC message will be displayed for 30
seconds after Unset, if confirmed alarm has been reported..
ARC message in line 1 of display (16 chars).
ARC message in line 2 of display (16 chars).
Enter a new name for your PARTSET A mode (e.g. Night
Mode).
Enter a new name for your PARTSET B mode (e.g. Floor 1
only).
Configure the options for PARTSET A/B alarm modes for a
single area installation if the function (multiple) Areas is not
activated. If the function is activated, the Partset options for
each area can be configured on the Areas [➙ 166]
configuration page..
Enter the number of digits for user codes (max. 8 digits).
Increasing the number of digits will add the relevant number
of zeros to the front of an existing code, e.g. an existing user
code of 2134 (4 digits) will change to 00002134 if the PIN
digits is set to 8.
If enabled, both PACE and PIN are required.
If enabled you cannot select your PIN. The PIN will
automatically be generated by the panel.
Enable for alerts to auto clear after 30 sec. in Unset mode.