2 X-BUS (2 spurs or 1 loop),
2 RS232 (to X-10 controller or external communication),
1 USB (PC connection),
1 SPC Fast Programmer,
SPC53xx: Additionally 1 Ethernet (RJ45)
Front spring tamper, 2 auxiliary tamper contact inputs
230 VAC, + 10%/ -15%, 50 Hz
250 mA T (replaceable part on mains terminal block)
SPC53xx: Max. 200 mA at 230 VAC
SPC53xx Controller: Max. 200 mA at 12 VDC
SPC53xx Controller: Max. 170 mA at 12 VDC (195 mA
with PSTN, 300 mA with GSM, 325 mA with PSTN &
GSM)
11-14 VDC in normal conditions (mains powered and fully
charged battery), min. 9.5 VDC when powered by
secondary device (before system shut down to battery
deep discharge protection)
Max. 5 % of output voltage
Auxiliary power (nominal)
SPC5320: YUASA NP7-12FR (7 Ah),
SPC5330: YUASA NP17-12FR (17 Ah), Battery not
supplied
SPC5320: Max. 72h,
SPC5330: Max. 24h
to 80% of battery capacity
Current limited to 1 A (fuse protected), deep discharge
protection at 10.5 VDC +/- 3 % (fault at deep discharge
voltage + 0.5 VDC)
On-site and remote upgrade for controller and peripherals
No calibration checks required (calibrated at
manufacturing)
Max. 90 % (non condensing)
SPC5320: 4.500 kg
SPC5330: 6.100 kg