Engineer programming via the browser
15
Changing system settings
163
Siemens AB
A6V10276959
Security Products
18.11.2011
Timer
Description
Default
TECH. DELAY
tech. delay attribute. (0 9999 seconds)
Fail To Set
FAIL TO SET
Number of seconds to display fail to set message on keypads
(0 until valid PIN is entered). (0 999 seconds)
10 sec.
Confirm
CONFIRM TIME
Note: Only available when Security Grade is
‘Unrestricted’ and ‘DD243’ is selected for ‘Confirmation’
variable. (See System Options [154])
This timer applies to the alarm confirmation feature and is
defined as the maximum time between alarms from two
different non overlapping zones that will cause a confirmed
alarm. (30 60 minutes)
30 min.
Exit*
EXIT TIME
!
The time period allowed for the user to exit the building after
setting the system. The exit time will be counted down at the
keypad as the buzzer beeps to indicate to the user that the
system will arm when the exit timer reaches zero.
45 sec.
Entry*
ENTRY TIME
!
The time period allowed for the user to UNSET the alarm
after opening an entry/exit zone of an armed system.
45 sec.
Frequent
FREQUENT
!
This attribute only applies to Remote Maintenance. The
number of hours a zone must open within if the zone is
programmed with the Frequent use attribute. (1 9999 hours)
336 hours (2
weeks)
Fire Pre-alarm
FIRE PRE-ALARM
Number of seconds to wait before reporting file alarm for
zones with ‘Fire pre-alarm’ attribute set. (1 999 seconds)
See Editing a Zone [ 165].
30 sec.
Fire recognition
FIRE RECOGNITION
Extra time to wait before reporting file alarm for zones with
Fire pre-alarm’ and ‘Fire Recognition’ attributes set. (1 999
seconds) See Editing a Zone [➙ 165].
120 sec.
Alarm abort
ALARM ABORT
Time after a reported alarm in which an alarm abort message
can be reported. (0 999 seconds))
30 sec.
Seismic Test Interval
SEISMIC AUTOTEST
The average period between seismic sensor automatic tests
(12 240 hours)
Note: To enable automatic testing, the Automatic Sensor Test
attribute must be enabled for a seismic zone.
168 hours.
Seismic Test Duration
SEISMIC TEST DUR
Maximum time (in seconds) that a seismic sensor takes to
trigger an alarm in response to the 'Seismic Test' output.
(3 - 120 seconds)
30 sec.
RF Output Time
RF OUTPUT
The time that the RF output will remain active on the system.
(0 999 seconds)
0 sec.
Time Sync Limit
TIME SYNC LIMIT
Time synchronisation only takes place if system time and
update time are outside this limit.
0 sec.
*NOTE: Entry and Exit timers are displayed on this page if the function (multiple)
Areas is not activated. If the function is activated, the Entry and Exit timers for each
area are located in the Area Configuration.