Audio
Up to 60 sec. pre / 60 sec. post audio recording
Field bus 1)
X-BUS on RS-485 (307 kb/s)
Number of field devices 2)
Max. 128 (32 keypads, 32 door-expanders, 64 input/output
expanders)
Connectable field devices
Keypads: SPCK42x, SPCK62x
Door expanders: SPCA210, SPCP43x
Expanders with I/O: SPCE65x, SPCE45x, SPCP33x,
SPCE110, SPCE120, SPCV32x
Interfaces
2 X-BUS (2 spurs or 1 loop),
2 RS232 (to X-10 controller or external communication),
1 USB (PC connection),
1 SPC Fast Programmer,
SPC63xx: Additionally 1 Ethernet (RJ45)
Tamper contact
Front spring tamper, 2 auxiliary tamper contact inputs
Power supply
Type A (per EN50131-1)
Mains voltage
230 VAC, + 10%/ -15%, 50 Hz
Mains fuse
250 mA T (replaceable part on mains terminal block)
Power consumption
SPC63xx: Max. 200 mA at 230 VAC
Operating current
SPC63xx Controller: Max. 200 mA at 12 VDC
Quiescent current
SPC63xx Controller: Max. 170 mA at 12 VDC (195 mA with
PSTN, 300 mA with GSM, 325 mA with PSTN & GSM)
Output voltage
11-14 VDC in normal conditions (mains powered and fully
charged battery), min. 9.5 VDC when powered by
secondary device (before system shut down to battery deep
discharge protection)
Low voltage trigger
7.5 VDC
Overvoltage protection
15.7 VDC
Peak to Peak ripple
Max. 5 % of output voltage
Auxiliary power (nominal)
Max. 750 mA at 12 VDC
Battery type
SPC6330: YUASA NP17-12FR (17 Ah), Battery not
supplied
Battery charger
SPC6330: Max. 24h to 80% of battery capacity
Battery protection
Current limited to 1 A (fuse protected), deep discharge
protection at 10.5 VDC +/- 3 % (fault at deep discharge
voltage + 0.5 VDC)
Software update
On-site and remote upgrade for controller and peripherals
Calibration
No calibration checks required (calibrated at manufacturing)
Servicable parts
No serviceable parts
Operating temperature
0 ~ +40 °C