NCK alarms/ISO alarms
06/2007 Overview of alarms
2-157
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
15300 Channel %1 block %2 invalid number-of-passed-blocks during block
search
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In the function "Block search with calculation" a negative number of passes has been entered in col-
umn P (number of passes). The permissible range of values is P 1 - P 9 999.
Reaction: Alarm display.
Remedy: Enter only positive number of passes within the range of values.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
15310 Channel %1 block %2 file requested during block search is not available
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: During block search, a target has been specified with a program that has not been loaded.
Reaction: Alarm display.
Remedy: Correct the specified search target accordingly or reload the file.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
15320 Channel %1 block %2 invalid block search command
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The block search command (type of search target) is smaller than 1 or greater than 5. It is entered in
column type of the block search window. Valid block search commands are:
TypeMeaning
1Search for block number
2Search for label
3Search for string
4Search for program name
5Search for line number in a file
Reaction: Alarm display.
Remedy: Change block search command.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
15330 Channel %1 block %2 invalid block number as search target
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Syntax error! Positive integers are allowed as block numbers. Block numbers must be preceded by ":"
and subblocks by an "N".
Reaction: Alarm display.
Remedy: Repeat the input with corrected block number.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
15340 Channel %1 block %2 invalid label as search target
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Syntax error! A label must have at least 2 but no more than 32 characters, and the first two characters
must be alphabetic or underscore characters. Labels must be concluded with a colon.
Reaction: Alarm display.
Remedy: Repeat the input with corrected label.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.