Remedy: Configure machine date $MN_HANDWHEEL_INPUT for a valid input for the corresponding hand-
wheel
Program Con-
tinuation:
Switch control OFF - ON.
4630 Invalid handwheel module for handwheel %1
Parameters: %1 = Handwheel module
Definitions: The reference in $MN_HANDWHEEL_MODULE for a corresponding entry in machine date array
$MN_HANDWHEEL_LOGIC_ADDRESS[] necessary for the configuration of PROFIBUS handwheels
is not available.
Reaction: Interface signals are set.
Alarm display.
Remedy: Configure the machine data $MN_HANDWHEEL_MODULE for the corresponding PROFIBUS hand-
wheel so that there is a valid reference to an entry in the machine data array
$MN_HANDWHEEL_LOGIC_ADDRESS[].
Program Con-
tinuation:
Switch control OFF - ON.
4631 Invalid handwheel slot for handwheel %1
Parameters: %1 = Handwheel slot
Definitions: The handwheel slot for handwheel %1 requested through the machine date
$MN_HANDWHEEL_INPUT is not available for PROFIBUS handwheels.
Reaction: Interface signals are set.
Alarm display.
Remedy: Configure machine date $MN_HANDWHEEL_INPUT to a valid handwheel slot for the corresponding
PROFIBUS handwheel.
Program Con-
tinuation:
Switch control OFF - ON.
4632 Logical PROFIBUS handwheel slot base address for handwheel %1 not
found
Parameters: %1 = Handwheel number
Definitions: The logical base address of the PROFIBUS handwheel slot in machine date array
$MN_HANDWHEEL_LOGIC_ADDRESS[] indexed in machine date $MN_HANDWHEEL_MODULE
was not found.
Reaction: Interface signals are set.
Alarm display.
Remedy: Check if $MN_HANDWHEEL_MODULE of the corresponding handwheel is correct. Check if indexed
logical base address of PROFIBUS handwheel slot in machine date array
$MN_HANDWHEEL_LOGIC_ADDRESS[] is correct.
Program Con-
tinuation:
Switch control OFF - ON.
5000 Communication job not executable %1
Parameters:
Definitions: The communication request (data exchange between NC and HMI,
for example: load an NC part program) cannot be executed due lack of memory. Cause: too many
parallel communication requests
Reaction: Alarm display.
Remedy: No remedy possible – the operation that produced to alarm must be repeated. Clear the alarm display
with Cancel.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.