10207 Channel %1 error when selecting or deselecting the digitize function
Parameters: %1 = Channel number
Definitions: An error has occurred on activating/deactivating the digitizing module; e.g. not in channel ready state,
already activated, etc.
Reaction: Alarm display.
Remedy: Press RESET.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
10208 Channel %1 continue program with NC start
Parameters: %1 = channel number
Definitions: After block search with calculation, the control is in the desired state.
The program can now be started with NC Start or the state can be changed for the time being with
overstore/jog.
Reaction: Interpreter stop
Alarm display.
NC Stop on alarm.
Remedy: Press NC Start
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
10209 Channel %1 internal NC stop after block search
Parameters: %1 = Channel number
Definitions: Internal alarm which only initiates the alarm response NC Stop.
The alarm is output in the following situations:
- If $MN_SEARCH_RUN_MODE bit 0 ==1 and the last action block is loaded in the main run after
block search. Alarm 10208 is then activated as a function of the VDI signal PLC -> NCK channel
DBB1.6.
- Search alarm 10208 has been suppressed by the PI service _N_FINDBL (third decade of the param-
eter supplied with "2"). Alarm 10209 is set as a function of whether or not a search ASUB has been
configured ( $MN_SEARCHRUN_MODE bit 1) with the end of the search ASUB or the loading of the
last action block in the main run.
Reaction: Interpreter stop
NC Stop on alarm.
Remedy: NC-Start
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
10225 Channel %1: command denied
Parameters: %1 = channel number
%2 = string (event name)
Definitions: The channel contains a command that cannot be executed.
Reaction: Alarm display.
Remedy: Press RESET
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
Clear alarm with the Delete key or NC START.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program