Overview of alarms 06/2007
Cycle alarms
2-324
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62184 Channel %1 block %2 : replace inclinable head: %4
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycle: CYCLE800.
Reaction: Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62300 Channel %1 Block %2: Check number of empirical value memory
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: --
Reaction: Alarm display.
Remedy: Check setpoint value
Increase parameter _TSA
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62304 Channel %1 Block %2: Allowance
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE974, CYCLE977, CYCLE978, CYCLE979,
CYCLE994.
Reaction: Alarm display.
Remedy: The difference between actual and setpoint value is larger than upper tolerance limit (parameter
_TUL).
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62308 Channel %1 Block %2: Variable column width not possible
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE105.
Unable to generate variable column widths, as no header available.
A fixed column width of 12 characters is used.
Reaction: Alarm display.
Remedy: Complete the header in _PROTVAL[0].
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62309 Channel %1 Block %2: Insufficient column width
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE105.
The value to be logged is larger than the column width.
Reaction: Alarm display.
Remedy: Adjust _PROTFORM[5] or change the header at variable column width.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62311 Channel %1 block %2: The maximum number of characters per line
_PROTFORM[1] is adjusted.
Parameters: %1 = Channel number
%2 = Block number, label channel number