Overview of alarms 06/2007
Cycle alarms
2-284
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
61175 Channel %1 block %2: angle of aperture _DF programmed too small
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The angle of aperture of the text in the engraving cycle is too small. This means that the text for
engraving does not fit in the specified angle.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Enter a larger angle of aperture.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61176 Channel %1 block %2: text length _DF programmed too small
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The text length in the engraving cycle is too short. This means that the text for engraving is longer than
the specified text length.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Enter longer text length
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61177 Channel %1 block %2: polar text length > 360 degrees
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In the engraving cycle, the polar text length must not exceed 360 degrees.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Enter shorter text length.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61178 Channel %1 block %2: code page not present
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The specified code page is not supported by the cycle.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Use code page 1252.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61179 Channel %1 block %2: character does not exist, no.: %4
Parameters: %1 = Channel number
%2 = Block number, label
%4 = Character number
Definitions: The character entered in the text for engraving cannot be milled.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Seitenansicht 283