Overview of alarms 06/2007
NCK alarms/ISO alarms
2-214
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
18101 Channel %1 block %2 invalid value assigned to FXST[]
Parameters: %1 = channel number
%2 = block number, label
Definitions: Only the range 0.0 - 100.0 is valid at the present time.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
18102 Channel %1 block %2 invalid value assigned to FXSW[]
Parameters: %1 = channel number
%2 = block number, label
Definitions: Only positive values including zero are valid at the present time.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
18300 Channel %1 block %2 frame: fine shift not possible
Parameters: %1 = channel number
%2 = block number, label
Definitions: Allocation of a fine offset to settable frames or the basic frame is not possible since MD 18600
MM_FRAME_FINE_TRANS is not equal to 1.
Reaction: Interpreter stop
Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department. Modify program or set MD 18600
MM_FRAME_FINE_TRANS to 1.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
18310 Channel %1 block %2 frame: illegal rotation
Parameters: %1 = channel number
%2 = block number, label
Definitions: Rotations are not possible with global frames.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
18311 Channel %1 block %2 frame: illegal instruction
Parameters: %1 = channel number
%2 = block number, label
Definitions: An attempt was made to read or write a frame which does not exist.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Modify part program.
Kommentare zu diesen Handbüchern