Overview of alarms 06/2007
NCK alarms/ISO alarms
2-204
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
17190 Channel %1 block %2 illegal T number
Parameters: %1 = channel number
%2 = block number, label
Definitions: In the displayed block, access is made to a T number (tool number) that is not initialized and therefore
not available.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Check tool call in the NC part program:
Correct tool number T... programmed?
Tool parameters P1 - P25 defined?
The dimensions of the tool edge must have been entered previously either on the operator panel or
via the RS-232-C.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
17191 Channel %1 block %2 T= %3 not existing, program %4
Parameters: %1 = channel number
%2 = block number, label
%3 = T number or T identifier
%4 = program name
Definitions: A tool identifier which the NC does not recognize was programmed.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: If the program pointer is at an NC block which contains the specified T identifier:
If the program is incorrect, remedy the error with a correction block and continue the program.
If the data block is missing, create one. You can do this by downloading a data block with all the
defined D numbers onto the NC (via MMC) and then continue the program.
If the program pointer is at an NC block which does not contain the specified T identifier:
The error occurred at an earlier point in the program where the T command appeared, but the alarm
was not output until the change command was detected.
If the program is incorrect - T5 programmed instead of T55 - the current block can be corrected with
a correction block; i.e. if only M06 is entered, you can correct the block with T55 M06. The incorrect
T5 line remains in the program until it is terminated by a RESET or end of program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
17194 Channel %1 block %2 no suitable tool found
Parameters: %1 = channel number
%2 = block number, label
Definitions: An attempt was made to access a tool which has not been defined.
The specified tool does not permit access.
A tool with the desired properties is not available.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Check access to tool:
Are the parameters of the NC command correctly programmed?
Does the status of the tool prevent access?
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
Seitenansicht 203