6530 Too many files in directory
Definitions: The number of files in one directory of the NC has reached the maximum limit.
Reaction: Alarm display.
Remedy: Delete or empty files (e.g. part programs) in the subdirectory affected.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
6540 Too many directories in the NC memory
Definitions: The number of directories in the NC file system (part of the NC memory) has reached the maximum
number possible.
Reaction: Alarm display.
Remedy: Delete or empty directories (e.g. workpiece) that are not required.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
6550 Too many subdirectories
Definitions: The number of subdirectories in a directory of the NC has reached the maximum limit.
Reaction: Alarm display.
Remedy: Please inform the authorized personnel/service department.
Delete or empty subdirectories in the respective directory, or
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
6560 Data format not allowed
Definitions: Illegal data have been entered in an NC file, e.g. binary data loaded as an ASCII file.
Reaction: Alarm display.
Remedy: Mark the file as binary data (e. g. extension: .BIN).
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
6570 NC memory full
Definitions: The NC card file system of the NC is full. The task cannot be executed. Too many system files were
created in the DRAM.
Reaction: Alarm display.
Remedy: Start fewer "Execute from external" processes.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
6580 NC memory full
Definitions: The NC card file system of the NCK is full. The task cannot be executed. To many files have been
loaded
Reaction: Alarm display.
Remedy: Delete or empty files (e.g. part programs).
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
6581 NC user memory full
Definitions: The DRAM file system of the user area is full. The order cannot be executed.
Reaction: Alarm display.
Remedy: Delete or unload files (e.g. parts programs)
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
6582 NC machine OEM memory full
Definitions: The DRAM file system of the machine OEM area is full. The order cannot be executed.
Reaction: Alarm display.
Kommentare zu diesen Handbüchern