NCK alarms/ISO alarms
06/2007 Overview of alarms
2-19
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
4012 Invalid identifier used in machine data %1[%2]
Parameters: %1 = string: MD identifier
%2 = index: MD array
Definitions: The selected identifier is invalid. The following are valid identifiers:
• AX1 - AXn: Machine axis identifiers
Reaction: NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Use the correct identifier.
Program Con-
tinuation:
Switch control OFF - ON.
4020 Identifier %1 used several times in machine data %2
Parameters: %1 = string: Identifier
%2 = string: MD identifier
Definitions: To determine the name in the channel-specific tables (arrays) for machine axes an identifier already
existing in the control has been used.
Reaction: NC not ready.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department.
Select for the identifier to be entered a character string that is not yet used in the system (max. 32
characters).
Program Con-
tinuation:
Teileprogramm neu starten.Clear alarm with the RESET key in all channels of this mode group.
Restart part program.
4021 Channel %1 identifier %2 used several times in machine data %3
Parameters: %1 = channel number
%2 = string: identifier
%3 = string: MD identifier
Definitions: To determine the name in the channel-specific tables for geometry axes and channel axes an identifier
already existing in the control has been used.
Reaction: NC not ready.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department.
Select for the identifier to be entered a character string that is not yet used in the system (max. 32
characters).
Program Con-
tinuation:
Switch control OFF - ON.
4030 Channel %1 axis identifier missing in machine data %2[%3]
Parameters: %1 = channel number
%2 = string: MD identifier
%3 = index: MD array index
Seitenansicht 18