NCK alarms/ISO alarms
06/2007 Overview of alarms
2-89
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
Remedy: Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM COR-
RECT. The correction pointer positions on the incorrect block.
Check the block structure and correct in accordance with the programming requirements.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12120 Channel %1 block %2 G function not separately programmed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The G function programmed in this block must be alone in the block. No general addresses or syn-
chronous actions may occur in the same block. These G functions are:
G25, G26Working area, spindle speed limitation
G110, G111, G112 Pole programming with polar coordinates
Example:
G4 F1000 M100: no M function allowed in the G4 block.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Program G function by itself in the block.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12140 Channel %1 block %2 functionality %3 not implemented
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Software construction in the source text
Definitions: In the full configuration of the control functions are possible that are not yet implemented in the current
version.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM COR-
RECT. The correction pointer positions on the incorrect block.
The displayed function must be removed from the program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12150 Channel %1 block %2 operation %3 not compatible with data type
Parameters: %1 = Channel number
%2 = Block number, label
%3 = String (violating operator)
Definitions: The data types are not compatible with the required operation (within an arithmetic expression or in a
value assignment).
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM COR-
RECT. The correction pointer positions on the incorrect block.
Change the definition of the used variables so that the required operations can be performed.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12160 Channel %1 block %2 range of values exceeded
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The programmed constant or the variable exceeds the value range that has previously been estab-
lished by the definition of data type.
Reaction: Correction block is reorganized.