NCK alarms/ISO alarms
06/2007 Overview of alarms
2-33
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
Program Con-
tinuation:
Switch control OFF - ON.
4300 Declaration in MD %1 is not allowed for axis %2.
Parameters: %1 = string: MD identifier
%2 = axis name, spindle number
Definitions: Geometry axes and spindles cannot be operated as concurrent positioning axes.
Reaction: Alarm display.
Remedy: Please inform the authorized personnel/service department. Reset MD 30450
IS_CONCURRENT_POS_AX for the axis concerned.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4310 Declaration in MD %1 index %2 is not allowed.
Parameters: %1 = string: MD identifier
%2 = index in MD array
Definitions: The MD values must be written in the array in ascending order.
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Correct the MD
Program Con-
tinuation:
Teileprogramm neu starten.Clear alarm with the RESET key in all channels of this mode group.
Restart part program.
4320 Axis %1 function %2 %3 and %4 not allowed
Parameters: %1 = string: Axis identifier
%2 = string: MD identifier
%3 = string: Bit
%4 = string: MD identifier
Definitions: The functions declared by the machine data specified cannot be activated at the same time for one
axis.
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Deactivate one of the functions.
Program Con-
tinuation:
Switch control OFF - ON.
4340 Channel %1 block %2 invalid transformation type in transformation no.
%3
Parameters: %1 = channel number
%2 = transformation number
Definitions: An invalid, i.e. undefined, number was entered in one of the machine data 24100 TRAFO_TYPE_1.
This alarm occurs only if a certain type of transformation is not possible in the specified control type.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy: Valid transformation type entered
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program