Overview of alarms 06/2007
NCK alarms/ISO alarms
2-166
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
16510 Channel %1 block %2 no facing axis for diameter programming available
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Diameter programming has been activated with the vocabulary word DIAMON although no facing axis
has been programmed in this NC block.
If the diameter axis is not a geometry axis, in the initial setting "DIAMON" the alarm appears as soon
as the control is switched on.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department.
Activate the modal G function DIAMON only in NC blocks containing a facing axis or deactivate diam-
eter program with DIAMOF.
In MD 20150 GCODE_RESET_VALUES[28], select "DIAMOF" for the initial setting.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
16520 Channel %1 axis %2, diameter programming active, function %3 is not
executed
Parameters: %1 = Channel
%2 = Axis, spindle
%3 = NC function
Definitions: The function is not executed with diameter programming active for the stated axis.
The following functions may be affected:
1 - Axis interchange
2 - Axis container rotation
Reaction: Interpreter stop
Local alarm reaction.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Disable diameter programming of the axis before activating the function.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
16600 Channel %1 block %2 spindle %3 gear stage change not possible
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Spindle number
Definitions: The programmed speed is outside the speed range of the set gear stage. In order to execute the pro-
grammed speed, the gear stage must be changed. In order to be able to execute the automatic gear
stage change (M40 is active), the spindle must be in speed control operation.
>The alarm will no longer be output after having set bit 30 (0x40000000) in MD 11410
SUPPRESS_ALARM_MASK. However, the function will not be affected by this.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: The changeover to speed control operation is performed by programming M3, M4 or M5. The M func-
tions can be written together with the S word in the same block.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
16670 Channel %1 block %2 following axis/spindle %3 maximum number of CP
modules (%4) has been exceeded
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Max. number of CP modules