Cycle alarms
06/2007 Overview of alarms
2-301
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
61269 Channel %1 block %2: External tool diameter too small
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Incorrect tool definition.
Alarm triggered by following cycle: CYCLE61.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check angle and diameter of the tool used.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61270 Channel %1 block %2: Chamfer width too small
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Chamfer width selected too small.
Alarm triggered by the following cycles: E_SP_CHA, F_SP_CHA.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Increase the chamfer width.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61271 Channel %1 block %2: Chamfer width > tool radius
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Chamfer width larger than tool radius.
Alarm triggered by following cycles: E_SP_CHA, F_SP_CHA.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Use a larger tool.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61272 Channel %1 block %2: Insertion depth too small
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Insertion depth on chamfering too small.
Alarm triggered by following cycles: E_SP_CHA, F_SP_CHA.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Increase the insertion depth.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
Seitenansicht 300
1 2 ... 296 297 298 299 300 301 302 303 304 305 306 ... 391 392

Kommentare zu diesen Handbüchern

Keine Kommentare

Whirlpool Raffreddamento per bevande manuali utente

Partendo da I

Cliccare su un alfabeto di seguito per far scorrere la lista completa dei modellif models starting with that letter

Modelli Tipo di Documento
IN SU 135/B G S
Istruzioni per l'uso       Whirlpool IN SU 135/B G S Instruction for Use, 32 pagine