NCK alarms/ISO alarms
06/2007 Overview of alarms
2-85
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
10934 Channel %1 block %2 array for contour segmentation is set too small
Parameters: %1 = channel number
%2 = block number, label
Definitions: The program in which the stock removal contour is programmed contains too many blocks with
motions in both axes in the machining plane (CYCLE 95).
Reaction: Local alarm reaction.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: The number of blocks in the contour program must be reduced. You should check the distribution of
the contour over several programs.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
10948 Channel %1 block %2 curve table %3: position jump at end of period
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Number of curve table
Definitions: A periodic curve table was defined in which the position of the following axis at the end of the table
was different to the position at the start of the table.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Correct the part program and start it again.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
10962 Channel %1 block %2 function %3 not possible with path correction
Parameters: %1 = channel number
%2 = block number, label
%3 = function name
Definitions: With this software release, the specified function can not yet be used together with tool radius com-
pensation. Please modify the part program or obtain a higher software version.
Reaction: Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12000 Channel %1 block %2 address %3 programmed repeatedly
Parameters: %1 = channel number
%2 = block number, label
%3 = source string of address
Definitions: Most addresses (address types) may only be programmed once in an NC block, so that the block infor-
mation remains unambiguous (e.g. X... T... F... etc. - Exception: G and M functions).
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM COR-
RECTION. The correction pointer positions on the incorrect block.
Remove from the NC program addresses that occur more than once (except for those where multiple
value assignments are allowed).
Check whether the address (e.g. the axis name) is specified via a user-defined variable (this may not
be easy to see if allocation of the axis name to the variable is performed in the program through com-