Cycle alarms
06/2007 Overview of alarms
2-277
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
61109 Channel %1 Block %2: Parameter _CDIR incorrectly defined
Parameters:
Definitions: Source (cycle):
POCKET3
POCKET4
Remedy: The cutting direction _CDIR parameter has been set to the wrong value and needs to be altered.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61110 Channel %1 Block %2: Finishing allowance at bottom > depth infeed
Parameters:
Definitions: Source (cycle):
POCKET3
POCKET4
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: The finishing allowance at the base has been specified to be larger than the maximum depth infeed;
either reduce the finishing allowance or increase the depth infeed.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61111 Channel %1 Block %2: Infeed width > Tool diameter
Parameters:
Definitions: Source (cycle):
CYCLE71
POCKET3
POCKET4
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: The programmed infeed width is greater than the diameter of the active tool. It must be reduced.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61112 Channel %1 Block %2: Tool radius negative
Parameters:
Definitions: Source (cycle):
CYCLE72
Remedy: The radius of the active tool is negative. This is not permitted.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61113 Channel %1 Block %2: Parameter _CRAD too large for corner radius
Parameters:
Definitions: Source (cycle):
POCKET3
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: The parameter for the corner radius _CRAD has been set too large. It must be decreased.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program