Overview of alarms 06/2009
NCK alarms
2-102
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Definitions: If an offset is active in the tool direction, block change is not possible if this would change the assign-
ment of the offset axes to the channel axes (plane change, tool change, cutter <=> turning tool, geom-
etry axis exchange).
Reaction: Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy: - Modify part program.
- Reduce the offset in tool direction to zero.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14199 [Channel %1: ] Block %2 illegal plane change for tool with diameter
component
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: If a tool has a wear or length component which is evaluated as a diameter for the facing axis (bit 0
and/or bit 1 in MD20360 $MC_TOOL_PARAMETER_DEF_MASK is set) and bit 2 of this MD is also
set, this tool may only be used in the plane active on tool selection. A plane change results in an alarm.
Reaction: Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy: Modify part program.
Reset bit 2 in MD20360 $MC_TOOL_PARAMETER_DEF_MASK.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14200 [Channel %1: ] Block %2 negative polar radius
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In the endpoint specification of a traversing block with G00, G01, G02 or G03 in polar coordinates, the
polar radius entered for the keyword RP=... is negative.
Definition of terms:
- Specification of end of block point with polar angle and polar radius, referring to the current pole (pre-
paratory functions: G00/G01/G02/G03).
- New definition of the pole with polar angle and pole radius, referring to the reference point selected
with the G function. G110 ... last programmed point in the plane, G111 ... zero point of the current
work, G112 ... last pole
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Correct NC part program - permissible inputs for the pole radius are only positive absolute values that
specify the distance between the current pole and the block end point. (The direction is defined by the
polar angle AP=...).
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14210 [Channel %1: ] Block %2 polar angle too large
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In specifying the endpoints in a traversing block with G00, G01, G02 or G03 in polar coordinates, the
value range of the polar angle programmed under the keyword AP=... has been exceeded. It covers
the range from -360 to +360 degrees with a resolution of 0.001 degrees.
Definition of terms:
- Specification of end of block point with polar angle and polar radius, referring to the current pole (pre-
paratory functions: G00/G01/G02/G03).
Seitenansicht 101