NCK alarms
06/2009 Overview of alarms
2-93
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Alarm display.
Remedy: - Raise the execution right to match the protection level of part program %3
- Assign a lower protection level to part program %3 or release (key switch protection level 0)
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14016 [Channel %1: ] Block %2 error when calling the subroutine via M/T
function
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The following conflict was detected in a subprogram call per M or T function:
In the block referenced by parameter %2:
- An M or T function replacement has already been activated
- A modal subprogram call is active
- A subprogram return jump is programmed
- An end of program is programmed
- An M98 subprogram call is active (only in external language mode)
- T function replacement by D function programming in the same part program line is not possible with
active TLC (G43/G44) in ISO2 system.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: An M or T function replacement is only possible if a subprogram call or return jump has not already
been performed as a result of other program constructs. The part program must be corrected accord-
ingly.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14017 [Channel %1: ] Block %2 syntax error when calling the subroutine via M
function
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: When calling M code subroutine with parameter transfer, an illegal syntax was detected:
- Address extension not programmed as a constant.
- M function value not programmed as a constant.
Note:
If a parameter transfer has been programmed via MD10718 $MN_M_NO_FCT_CYCLE_PAR for an
M function replacement, the following restriction applies to this M function: both the address extension
and the M function value must be programmed for replacement as constants.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Change the programming of the M function.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14018 [Channel %1: ] Block %2 parts program command %3 not executable
(protection level setpoint value / actual value: %4)
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Programmed command
%4 = Protection level of the command / current protection level
Definitions: To parts program command %3, a protection level has been assigned that is logically higher (smaller
in value) than the current access right, or the command does not exist in the current control configu-
ration.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Modify parts program. Please see the Siemens Progamming Guide or OEM documentation for the