Overview of alarms 06/2009
Cycle alarms
2-254
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61607 [Channel %1: ] Block %2: Starting point incorrectly programmed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The starting point reached before the cycle call does not lie outside the rectangle described by the
contour subroutine. Alarm triggered by following cycle: CYCLE95.
Remedy: Check starting point prior to cycle call.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61608 [Channel %1: ] Block %2: Incorrect tool point direction programmed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycles: CYCLE94, CYCLE96.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: A cutting edge position 1...4, matching the undercut form, must be programmed.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61609 [Channel %1: ] Block %2: Shape incorrectly defined
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycles: CYCLE94, CYCLE96, LONGHOLE, POCKET3, SLOT1.
Remedy: Check parameter for the undercut form or groove form or pocket.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61610 [Channel %1: ] Block %2: No infeed depth programmed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycles: CYCLE76, CYCLE77, CYCLE96.
Remedy: Check parameter MID.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61611 [Channel %1: ] Block %2: No point of intersection found
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: No intersection could be calculated with the contour. Alarm triggered by following cycle: CYCLE95.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check contour programming or modify infeed depth.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61612 [Channel %1: ] Block %2: Thread finishing not possible
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycles: CYCLE97, CYCLE98.
Remedy: Check the conditions for thread finishing.