NCK alarms
06/2009 Overview of alarms
2-69
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Definitions: The programmed function has been predefined; no parameters are allowed in its call. The first unex-
pected parameter is displayed.
Example: On calling the predefined subroutine TRAFOF (switching off a transformation) parameters
have been transferred (one or more).
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM COR-
RECT. The correction pointer positions on the incorrect block.
Program function without parameter transfer.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12100 [Channel %1: ] Block %2 number of passes %3 not permissible
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Number of passes
Definitions: The subroutines called with MCALL are modal, i.e. after each block with positional information a rou-
tine run is automatically performed once. For this reason, programming of the number of passes under
address P is not allowed.
The modal call is effective until another MCALL is programmed, either with a new subroutine name or
without (delete function).
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM COR-
RECT. The correction pointer positions on the incorrect block.
Program the subroutine call MCALL without number of passes.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12110 [Channel %1: ] Block %2 block syntax cannot be interpreted
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The addresses programmed in the block are not permissible together with the valid syntax defining G
function, e.g. G1 I10 X20 Y30 F1000.
An interpolation parameter must not be programmed in the linear block.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM COR-
RECT. The correction pointer positions on the incorrect block.
Check the block structure and correct in accordance with the programming requirements.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12120 [Channel %1: ] Block %2 G function not separately programmed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The G function programmed in this block must be alone in the block. No general addresses or syn-
chronous actions may occur in the same block. These G functions are:
G25, G26: Working area and spindle speed limitation
G110, G111, G112: Pole programming with polar coordinates
G92: Spindle speed limitation with v constant
STARTFIFO, STOPFIFO: Control of preprocessing buffer
E.g. G4 F1000 M100: no M function allowed in the G4 block.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Program G function by itself in the block.