Overview of alarms 06/2009
Cycle alarms
2-242
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Definitions: The alarm is triggerd by the following cycles: CYCLE997, CYCLE119
Remedy: Set MD 28081>0, $P_CHBFRMASK>0
61413 [Channel %1: ] Block %2: check setpoint of ball diameter, _SETVAL<=0
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE997
Remedy: Check setpoint value of spherical diameter.
61414 [Channel %1: ] Block %2 : distortion of triangle over limit
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE997, CYCLE119
Remedy: Check the setpoint and actual values
61415 [Channel %1: ] Block %2: check probe / machining plane
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE971
Remedy: Enter permissible probe (_TP[x,8], _TPW[x,8]) for machining plane or change machining plane.
61416 [Channel %1: ] Block %2: adapt array size %4!
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: "Adjust field size _TP[ ]/_CVAL[0]!" or "Adjust field size _WP[ ]/_CVAL[1]!" or "Adjust field size _KP[
]/_CVAL[2]!" or "Adjust field size _TWP[ ]/_CVAL[3]!". Check probe/machining plane.
Alarm triggered by following measuring cycles: all measuring cycles.
Remedy: Adjust _CVAL entry with the number of available probe or calibration block data fields.
61417 [Channel %1: ] Block %2: Probe will collide with the carrier of the
reference groove.
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following measuring cycles: CYCLE973
Remedy: Take up collision-free initial position of the axes involved in the measuring process.
61418 [Channel %1: ] Block %2: Protocol file too small, check MD11420:
LEN_PROTOCOL_FILE.
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: Alarm can be triggered by following measuring cycle: CYCLE106
Remedy: Check MD11420: LEN_PROTOCOL_FILE.
61419 [Channel %1: ] Block %2: Check probe calibration with reference to
center of ball/circumference of ball.
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following measuring cycles: CYCLE974, CYCLE994, CYCLE977,
CYCLE978, CYCLE979, CYCLE997, CYCLE998
Remedy: The workpiece probe must be calibrated according to its use in the measuring cycles.
61420 [Channel %1: ] Block %2: Check calibration of multi/mono probes.
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following measuring cycles: CYCLE974, CYCLE994, CYCLE977,
CYCLE978, CYCLE979, CYCLE997, CYCLE998
Remedy: The workpiece probe must be calibrated according to its type and use.