06/2009 List of action numbers
3-295
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
No. 17, PROGCANCELSUB
No. 18, SINGLEBLOCKSTOP
No. 19, SINGLEBLOCKOFF
No. 20, SINGLEBLOCK_IPO
No. 21, SINGLEBLOCK_DECODIER
No. 22, SINGLEBLOCK_MAINBLOCK
Explanation Abort subroutine processing (VDI signal: Program level abort).
Cause 1. Nesting depth too great
2. The active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
Remedy Abort program
Explanation Activate single block (VDI signal: Activate single block)
Cause -
Remedy -
Explanation Deactivation of single block (VDI signal: Activate single block)
Cause -
Remedy -
Explanation Activate main run single block (OPI variable and VDI signal: Activate single block)
Cause -
Remedy -
Explanation Activate decoding single block (OPI variable and VDI signal: Activate single block)
Cause 1. Nesting depth too great
2. The active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
Remedy Wait until the preceding ASUB is complete or
Abort program
Explanation Activate main run single block (OPI variable and VDI signal: Activate single block
Cause -
Remedy -