Siemens SINUMERIK 802D sl Betreibershandbuch Seite 117

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 340
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 116
NCK alarms
06/2009 Overview of alarms
2-117
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
- TURN>0: alarm display because the circle radius is infinitely great.
- TURN=0 and CIP specified between initial and end points. A straight line is generated between the
initial and end points (without alarm message).
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Locate the position of the intermediate point with the parameters I, J and K in such a way that it actually
is located between the initial and end points of the circle or do not make use of this type of circle pro-
gramming and instead program the circle with radius or opening angle or center point parameters.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
15030 [Channel %1: ] Block %2 different measurement system settings
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The INCH or METRIC instruction describes the system of measurement in which the data blocks have
been read from the control. In order to prevent the incorrect interpretation of data intended for a par-
ticular system of measurement, a data block is only accepted if the above instruction matches the
active system of measurement.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Change the system of measurement or load a data block which matches the system of measurement.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
15100 [Channel %1: ] Block %2 REORG abort caused by log file overflow
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In order to synchronize the preprocessing run and the main run with REORG, the control accesses
modification data which are maintained in a logfile. The alarm indicates that no more capacity is avail-
able in the logfile for the specified block in the channel.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department. No remedial measures are available for
the further execution of the current part program, however:
1. Reduce log file size requirement by:
Reducing the distance between the preprocessing and the main run via appropriate preprocessing
stops STOPRE.
2. Increase the size of the logfile by means of the channel-specific machine data:
Modify MD28000 $MC_MM_REORG_LOG_FILE_MEM and
Modify MD 28010 $MC_MM_NUM_REORG_LUD_MODULES
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
15110 [Channel %1: ] Block %2 REORG not possible
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In order to synchronize the preprocessing run and the main run with REORG, the control accesses
modification data which are maintained in a logfile. The alarm indicates that no more capacity is avail-
able in the logfile for the specified block in the channel.
The alarm message means that the logfile has been deleted in order to obtain additional memory for
program reorganization. Consequently, it is no longer possible to REORG the preprocessing memory
up to the next coincidence point.
Reaction: Alarm display.
Remedy: Please inform the authorized personnel/service department. No remedial measures are available for
the further execution of the current part program, however:
1. Reduce log file size requirement by:
Seitenansicht 116