List of action numbers 06/2009
3-302
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
No. 58, WAITE
No. 59, INIT_SYNC
No. 60, HMICMD
No. 61, PROGMODESLASHON
No. 62, PROGMODESLASHOFF
Explanation Wait for end of program (channel communication, NC block: WAITE).
Cause -
Remedy -
Explanation Program selection from another channel, synchronously (channel communication, NC
block: INIT + SYNC).
Cause -
Remedy -
Explanation Wait until acknowledgement from HMI (NC block, MMC_CMD)
Cause -
Remedy -
Explanation Activate the skip-block function (VDI signal: Skip block).
Cause Nesting depth too great
Remedy Wait until the preceding ASUB is complete or
Abort program
Explanation Deactivate the skip-block function (VDI signal: Skip block).
Cause Nesting depth too great
Remedy Wait until the preceding ASUB is complete or
Abort program