Cycle alarms
06/2009 Overview of alarms
2-195
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Alarm display.
Remedy: Program tool (T).
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61010 [Channel %1: ] Block %2: Finishing allowance too large
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The finishing allowance for the base is greater than the total depth. Alarm triggered by following cycle:
CYCLE72.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Reduce finishing allowance.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61011 [Channel %1: ] Block %2: Scaling not permissible
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: A scale factor is active which is illegal for this cycle. Alarm triggered by following cycles: CYCLE71,
CYCLE72.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Modify scale factor.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61012 [Channel %1: ] Block %2: Different scaling in planes
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycles: CYCLE76, CYCLE77.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61013 [Channel %1: ] Block %2: Basic settings were changed, program cannot
be executed
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The basic settings are not compatible with the generated program. Alarm triggered by following
cycles: E_CP_CE, E_CP_CO, E_CP_DR, F_CP_CE, F_CP_CO, F_CP_DR.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check and, if necessary, change the basic settings.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program