Cycle alarms
06/2009 Overview of alarms
2-263
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
61814 [Channel %1: ] Block %2: Polar coordinates not possible with cycle
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: --
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61815 [Channel %1: ] Block %2: G40 not active
Parameters: %1 = Channel number
%2 = Block number
Definitions: G40 was inactive before the cycle call.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61816 [Channel %1: ] Block %2: Axes not on reference point
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: --
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61817 [Channel %1: ] Block %2: Axis coordinates within protection zone
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: --
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61818 [Channel %1: ] Block %2: Axis range limits are equal
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: --
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program