SINUMERIK 802D sl, Diagnostics Manual, 06/2009
No. 116, TOOLCHANGECMDON
No. 117, TOOLCHANGECMDOFF
No. 118, SIVLIMCHANGE
No. 119, STOPRUN
No. 120, SINGLEAX_LIFTFAST_OFF_MASTER
No. 121, SINGLEAX_STOP_LIFTOFF_MASTER
Explanation Activate tool-management commands (Ch. VDI signal).
Cause The NCK channel is in a state other than "ready"
Remedy Abort the program or process with the Reset key or wait for end of program.
Explanation Deactivate tool-management commands (Ch. VDI signal).
Cause The NCK channel is in a state other than "ready"
Remedy Abort the program or process with the Reset key or wait for end of program.
Explanation Selection of desired safety limitations (SGE) (always allowed).
Cause -
Remedy -
Explanation Stop run, i.e., the NCK has automatically stopped at an OPI-defined block
Cause 1. Controller is not in automatic mode.
Remedy -
Explanation Rapid lift with a single axis
Cause The axis is not controlled by the PLC.
Remedy -
Explanation Rapid lift with a single axis has been stopped
Cause The axis is not controlled by the PLC and the single axis is not executing a rapid lift
Remedy -