Overview of alarms 06/2009
NCK alarms
2-112
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Alarm display.
Remedy: - Use the GET command to get axis %2 in the channel in which the transformation is to be selected.
- Select the transformation by means of the part program command.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
14750 [Channel %1: ] Block %2 too many auxiliary functions programmed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: More than 10 auxiliary functions have been programmed in an NC block.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Check whether all auxiliary functions are necessary in one block - modal functions need not be
repeated. Create separate auxiliary function block or divide the auxiliary functions over several blocks.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14760 [Channel %1: ] Block %2 auxiliary function of a group programmed
repeatedly
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The M and H functions can be divided up as required over machine data in groups in any variation.
Auxiliary functions are thus put into groups that mutually preclude several individual functions of one
group. Within one group only one auxiliary function is advisable and permissible.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department. Only program one help function per help
function group. (For the group division, see the machine manufacturer's programming guide).
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14762 [Channel %1: ] Block %2 too many PLC variables programmed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The number of programmed PLC variables has exceeded the maximum permissible number. The
number is set in MD 28150 $MC_MM_NUM_VDIVAR_ELEMENTS.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Modify part program or machine data.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
14770 [Channel %1: ] Block %2 auxiliary function programmed incorrectly
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The permissible number of programmed auxiliary functions per NC block has been exceeded or more
than one auxiliary function of the same auxiliary function group has been programmed (M and S func-
tion).
In the user-defined auxiliary functions, the maximum number of auxiliary functions per group in the
NCK system settings has been defined for all auxiliary functions by means of the MD11100
$MN_AUXFU_MAXNUM_GROUP_ASSIGN (default: 1)
For each user-defined auxiliary function to be assigned to a group, the assignment is effected through
4 channel-specific machine data.