NCK alarms
06/2009 Overview of alarms
2-15
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Remedy: Please inform the authorized personnel/service department. The entries for the indices for the
machine axes used in the channels must be contiguous in table MD20070
$MC_AXCONF_MACHAX_USED. Channel axis gaps must be enabled via
MD11640$MN_ENABLE_CHAN_AX_GAP.
Program Con-
tinuation:
Switch control OFF - ON.
4002 [Channel %1: ] Machine data %2[%3] assigns an axis not defined in
channel
Parameters: %1 = Channel number
%2 = String: MD identifier
%3 = Index: MD array index
Definitions: Only axes that have been activated in the channel by means of MD20070
$MC_AXCONF_MACHAX_USED [kx]=m may be declared as geometry axes or transformation axes
by means of the MD20050 $MC_AXCONF_GEOAX_ASSIGN_TAB [gx]=k.
gx: Geometry axis index,
kx: Channel axis index,
k: Channel axis no.,
m: Machine axis no
Reaction: NC not ready.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department.
Correct
- MD20050 $MC_AXCONF_GEOAX_ASSIGN_TAB
- MD24... $MC_TRAFO_AXES_IN_...
- MD24... $MC_TRAFO_GEOAX_ASSIGN_TAB_...
- MD22420 $MC_FGROUP_DEFAULT_AXES
- and/or MD20070 $MC_AXCONF_MACHAX_USED.
Program Con-
tinuation:
Switch control OFF - ON.
4004 [Channel %1: ] Machine data %2 axis %3 defined repeatedly as geometry
axis
Parameters: %1 = Channel number
%2 = String: MD identifier
%3 = Axis index
Definitions: An axis may only be defined once as a geometry axis.
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Correct MD20050 $MC_AXCONF_GEOAX_ASSIGN_TAB.
Program Con-
tinuation:
Switch control OFF - ON.