Overview of alarms 06/2009
Cycle alarms
2-200
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
61107 [Channel %1: ] Block %2: First drilling depth incorrectly defined
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: First drilling depth is in the opposite direction to the total drilling depth. Alarm triggered by following
cycle: CYCLE83.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Modify drilling depth.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61108 [Channel %1: ] Block %2: Values for parameters _RAD1 and _DP1 not
permissible
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The parameters _RAD1 and _DP for defining the path for the depth infeed have been incorrectly spec-
ified. Alarm triggered by following cycles: POCKET3, POCKET4.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Modify parameter.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61109 [Channel %1: ] Block %2: Parameter _CDIR incorrectly defined
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The value of the parameter for the cutting direction _CDIR has been incorrectly defined. Alarm trig-
gered by following cycles: POCKET3, POCKET4.
Remedy: Change parameter _CDIR.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61110 [Channel %1: ] Block %2: Finishing allowance at bottom > depth infeed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The finishing allowance at the base has been specified greater than the maximum depth infeed. Alarm
triggered by following cycles: POCKET3, POCKET4.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Either reduce finishing allowance or increase depth infeed.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61111 [Channel %1: ] Block %2: Infeed width > Tool diameter
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The programmed infeed width is greater than the diameter of the active tool. Alarm triggered by fol-
lowing cycles: CYCLE71, POCKET3, POCKET4.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Infeed width must be reduced.
Seitenansicht 199