Cycle alarms
06/2009 Overview of alarms
2-203
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
61121 [Channel %1: ] Block %2: Number of teeth per cutting edge is missing
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: No value was entered for the number of teeth per cutting edge. Alarm triggered by following cycles:
CYCLE70.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Enter the number of teeth/cutting edges for the active tool into the tool list.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61122 [Channel %1: ] Block %2: Safety distance incorrectly defined in plane
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The safety clearance is negative or zero. This is not allowed.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Define the safety clearance.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61123 [Channel %1: ] Block %2: CYCLE72 cannot be simulated
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycle: CYCLE72.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61124 [Channel %1: ] Block %2: Infeed width is not programmed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycle: CYCLE71.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: With active simulation without tool, a value for the infeed width _MIDA must always be programmed.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61125 [Channel %1: ] Block %2: Technology selection in parameter _TECHNO
incorrectly defined
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycles: CYCLE84, CYCLE840.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check parameter _TECHNO.