Overview of alarms 06/2009
NCK alarms
2-84
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
12540 [Channel %1: ] Block %2 Block is too long or too complex
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The maximum internal block length after translator processing must not exceed 256 characters. After
editing, for example, several macros in the block or a multiple nesting, this limit can be exceeded.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM COR-
RECT. The correction pointer positions on the incorrect block.
Divide up the program block into several subblocks.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12550 [Channel %1: ] Block %2 name %3 not defined or option/function not
activated
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Source symbol
Definitions: The identifier displayed has not been defined before being used.
-
_N_SMAC_DEF
_N_MMAC_DEF
_N_UMAC_DEF
_N_SGUD_DEF
_N_MGUD_DEF
_N_UGUD_DEF
Variable: DEF statement is missing
Program: PROC declaration is missing
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Press the NC Stop key and select the function "Compensation block" with the softkey PROGRAM
CORRECT. The cursor positions itself on the incorrect block.
- Correct the name used (writing error)
- Check definitions of variables, subroutines and macros
- Declare subroutine with EXTERN, load subroutine to SPF-Dir
- Check interface definition of subroutine
- Check options. See also MD10711 $MN_NC_LANGUAGE_CONFIGURATION.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12552 [Channel %1: ] Block %2 tool/magazine OEM parameter not defined.
Option not set. Option not set.
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The programmed $TC_... Cx system variable is not known in the control.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: - Correct the name used (writing error)
- $TC_DPCx, $TC_TPCx, $TC_MOPCx, $TC_MAPCx, $TC_MPPCx, $TC_DPCSx, $TC_TPCSx,
$TC_MOPCSx, $TC_MAPCSx, $TC_MPPCSx; with x=1,...10
- These are the OEM parameters of the tools magazines, The corresponding machine data value is
set to < 10, or the option 'TM OEM parameters' has not been set.
- Use correct parameter number, or - if the name cannot be changed - set machine data correction
(see MD18096 $MN_MM_NUM_CC_TOA_PARAM, ... MD18206
$MN_MM_NUM_CCS_TOA_PARAM, ...). )
- Check the option (machine data are only effective when the option is enabled).