Alarm triggered by following cycles: ASUP, E_TR_CON, F_TR_CON.
Remedy: Start the tool spindle before machining the thread.
62201 [Channel %1: ] Block %2: Z offset does not influence the retraction
planes.
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The retraction planes refer to the workpiece. Therefore, programmable offsets do not influence the
retraction planes.
Alarm triggered by following cycle: F_SP_RP.
Remedy: Ensure that the offset will not cause a collision.
Then start the NC.
The alarm can be suppressed via display machine data 9898.
62202 [Channel %1: ] Block %2: NOTICE: tool travels directly to machining!
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: After block search a position is to be reached by direct approach.
Alarm triggered by following cycle: F_TFS.
Remedy: Check whether the desired position can be reached without collision.
Then execute an NC start.
62300 [Channel %1: ] Block %2: Check number of empirical value memory
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: --
Reaction: Alarm display.
Remedy: Check setpoint value
Increase parameter _TSA
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62303 [Channel %1: ] Block %2: Safety margin exceeded
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy: -Check setpoint value
-Increase parameter _TSA
62304 [Channel %1: ] Block %2: Allowance
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE974, CYCLE977, CYCLE978, CYCLE979,
CYCLE994.
Reaction: Alarm display.
Remedy: The difference between actual and setpoint value is larger than upper tolerance limit (parameter
_TUL).
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62305 [Channel %1: ] Block %2: Dimension too small
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE974, CYCLE977, CYCLE978, CYCLE979,
CYCLE994
Remedy: The difference between actual and setpoint value is smaller than lower tolerance limit (parameter