Overview of alarms 06/2009
Cycle alarms
2-196
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
61014 [Channel %1: ] Block %2: Return plane exceeded
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: Alarm triggered by following cycles: CYCLE72.
Remedy: Check parameter RTP.
61015 [Channel %1: ] Block %2: Contour is not defined
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: Alarm triggered by following cycles: .
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61016 [Channel %1: ] Block %2: System frame for cycles missing
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: All measuring cycles can trigger this alarm.
Remedy: Set MD 28082: MM_SYSTEM_FRAME_MASK, Bit 5=1.
61017 [Channel %1: ] Block %2: function %4 not present in NCK
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: Alarm triggered by following cycles: .
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61018 [Channel %1: ] Block %2: function %4 not executable with NCK
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: Alarm triggered by following cycles: .
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61019 [Channel %1: ] Block %2: Parameter %4 incorrectly defined
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: Alarm triggered by following cycles: CYCLE60, CYCLE83.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check the value of the parameter.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program